Characteristics
Main range of product Zelio Controlproduct or component type Modular measurement and control relaysrelay type Control relaynetwork number of phases 3 phasesrelay name RM22TGrelay monitored parameters Phase sequence
Phase failure detection (2 or more phase cut)time delay type Withoutswitching capacity in VA 2000 VAmeasurement range 183...528 V voltage ACComplementary reset time 1500 ms at maximum voltagemaximum switching voltage 250 V ACminimum switching current 10 mA at 5 V DCmaximum switching current 8 A AC[Us] rated supply voltage 208...480 V ACsupply voltage limits 183…528 V ACoperating limits 183...528 V ACpower consumption in VA 15 VA at 480 V AC 60 Hzvoltage detection threshold < 100 V ACsupply voltage frequency 50...60 Hz +/- 10 %output contacts 2 C/Orun-up delay at power-up 650 msresponse time <= 200 msovervoltage category III conforming to IEC 60664-1
III conforming to UL 508insulation resistance > 100 MOhm at 500 V DC conforming to IEC 60255-27mounting position Any positionconnections - terminals Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable endtightening torque 0.6…1 N.m conforming to IEC 60947-1housing material Self-extinguishing plasticstatus LED LED (yellow)relay ON:
LED (green)power ON:mounting support 35 mm DIN rail conforming to EN/IEC 60715electrical durability 100000 cyclesmechanical durability 10000000 cyclesutilisation category AC-15 conforming to IEC 60947-5-1
DC-13 conforming to IEC 60947-5-1
AC-1 conforming to IEC 60947-4-1
DC-1 conforming to IEC 60947-4-1safety reliability data MTTFd = 924.6 years
B10d = 850000contacts material Cadmium freewidth 22.5 mmnet weight 0.09 kgEnvironment immunity to microbreaks 10 mselectromagnetic compatibility Immunity for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-1
Immunity for industrial environments conforming to EN/IEC 61000-6-2
Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3
Emission standard for industrial environments conforming to EN/IEC 61000-6-4
Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2
Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test - test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test - test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4
Surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5
Surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5
Conducted and radiated emissions class B group 1 conforming to CISPR 11
Conducted and radiated emissions class B conforming to CISPR 22standards EN/IEC 60255-1product certifications CE
EAC
China RoHS
RCM
GL
CSA
UL
CCCambient air temperature for storage -40…70 °Cambient air temperature for operation -20…50 °C at 60 Hz
-20…60 °C at 50 Hz AC/DCrelative humidity 93…97 % at 25…55 °C conforming to IEC 60068-2-30vibration resistance 0.075 mm (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6
1 gn (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6
0.035 mm (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6
0.5 gn (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6shock resistance 15 gn (duration = 11 ms) for not in operation conforming to IEC 60068-2-27
5 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27IP degree of protection IP20 (terminals) conforming to IEC 60529
IP40 (housing) conforming to IEC 60529
IP50 (front panel) conforming to IEC 60529pollution degree 3 conforming to IEC 60664-1
3 conforming to UL 508dielectric test voltage 2.5 kV, 1 min AC 50 Hz conforming to IEC 60255-27Packing Units Package 1 Weight 0.103 kgPackage 1 Height 0.250 dmPackage 1 width 0.820 dmPackage 1 Length 0.950 dmOffer Sustainability Sustainable offer status Green Premium productREACh Regulation EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS DeclarationMercury free YesRoHS exemption information China RoHS Regulation Environmental Disclosure Circularity Profile WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins -
View more
Documents
Language- All Languages11
- English11
- Chinese2
- French2
- German2
- Italian2
- Spanish2
CatalogueFormatSizeDateAdd to My Documentsprp.document.label.format pdfSize 8.1 MBDate 24/06/19CADFormatSizeDateAdd to My DocumentsCertificateFormatSizeDateAdd to My DocumentsCCC Certificate RM22 RM35 (Version 1.0)DescriptionCCC Certificate 2014010303743696prp.document.label.format pdfSize 1.8 MBDate 28/10/19DescriptionCCC Certificate 2014010303743696UL Listed RM17, RM22, RM35, RM8487 (Version 1.0)Files in documentDescriptionNRNT_NRNT7_E173076_Controlprp.document.label.format zipSize 949 KBDate 19/05/15Files in documentDescriptionNRNT_NRNT7_E173076_ControlCSA Certificate RM17, RM22, RM35, RM8487 (Version 1.0)DescriptionMC248382_Class 3211-07_Controlprp.document.label.format htmSize 213 BDate 18/05/15DescriptionMC248382_Class 3211-07_ControlInstruction sheetFormatSizeDateAdd to My Documentsprp.document.label.format pdfSize 3.8 MBDate 1/06/20China RoHS declarationFormatSizeDateAdd to My DocumentsRM22TG20 : RM22TG20_ROHS_CHINA_DECLARATIONDescriptionRM22TG20_ROHS_CHINA_DECLARATIONprp.document.label.format pdfSize 195.3 KBDate 15/09/20DescriptionRM22TG20_ROHS_CHINA_DECLARATIONEnd of Life InformationFormatSizeDateAdd to My Documentsprp.document.label.format pdfSize 5.4 MBDate 1/05/19EU RoHS DeclarationFormatSizeDateAdd to My DocumentsRM22TG20 : RM22TG20_ROHS_DECLARATIONDescriptionRM22TG20_ROHS_DECLARATIONprp.document.label.format pdfSize 195.3 KBDate 15/09/20DescriptionRM22TG20_ROHS_DECLARATIONProduct Environmental ProfileFormatSizeDateAdd to My Documentsprp.document.label.format pdfSize 5.4 MBDate 1/05/19REACh DeclarationFormatSizeDateAdd to My DocumentsRM22TG20 : RM22TG20_REACH_DECLARATIONDescriptionRM22TG20_REACH_DECLARATIONprp.document.label.format pdfSize 195.3 KBDate 15/09/20DescriptionRM22TG20_REACH_DECLARATION -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.-
Please inform me about the right voltage level and type (AC or DC) of the probe of RM35LM33MW relay (2007 Zelio Control catalogue page 56)! I see it i...
Related ranges: Zelio Control
-
What kind of application is this relay rm35s0mw built for? How to use it ? Is there some limitation?
Related ranges: Zelio Control
-
How to use RM35LM33MW to identify the liquid resistance?
Facts and Changes RM35LM33MW - Zelio Control Measurement Relays Level control relays
-
Can the RM35JA31MW monitor positive and negative currents?
Environment: Zelio Control and Measurement Relays
-
What does the red LED indicate on the RM4TU relay when it is on?
Product Line: Zelio Industrial Measurement and Control Relays
-
-
Dimensions Drawings
Dimensions -
Mounting and Clearance
Mounting and ClearanceRail Mounting
-
Connections and Schema
3-Phase Control RelayWiring Diagram

L1,L2,L3 : Supply to be monitored
11-14,12 : 1st C/O contact of output relay
21-24,22 : 2nd C/O contact of output relay
-
Technical Description
Function DiagramPhase Sequence Control and Total Loss of Phase Detection
LegendTr Response time on appearance of a fault
L1, L2, L3 Phases of the supply voltage monitored
R - R1/R2 Output relay(s),
Relay status: black color = energized.