Welcome to the Schneider Electric corporate Website

Select your location

Welcome the the Schneider Electric French website. It looks like you are located in the United States, would you like to change your location?

Traduisez en francais
View all   TeSys F
Schneider Electric LC1F6304 Image

Roll over image to zoom in

LC1F6304

Green premium brand logo
Schneider Electric LC1F6304 Image
    LC1F6304
    Green premium brand logo

    TeSys F contactor - 4P(4 NO)-AC-1 <= 440V 1000A with coil LX1/ LX9 - 48…1000V AC 40/400Hz, LX4 - 48...440V DC

    Show more characteristics
    The maximum number of products that can be compared is 4. Remove already added products.

    • Main
      range
      TeSys
      product name
      TeSys F
      product or component type
      Contactor
      device short name
      LC1F
      contactor application
      Resistive load
      utilisation category
      AC-1
      poles description
      4P
      power pole contact composition
      4 NO
      [Ue] rated operational voltage
      <= 1000 V AC 50/60 Hz
      <= 460 V DC
      [Ie] rated operational current
      1000 A (at <40 °C) at <= 440 V AC AC-1
      Complementary
      [Uc] control circuit voltage
      48...1000 V AC 40...400 Hz with LX1/LX9 coil
      48...440 V DC with LX4 coil
      [Uimp] rated impulse withstand voltage
      8 kV
      overvoltage category
      III
      [Ith] conventional free air thermal current
      1000 A (at 40 °C)
      1250 A
      Irms rated making capacity
      6300 A AC conforming to IEC 60947-4-1
      rated breaking capacity
      5040 A conforming to IEC 60947-4-1
      [Icw] rated short-time withstand current
      5050 A 40 °C - 10 s
      4400 A 40 °C - 30 s
      3400 A 40 °C - 1 min
      2200 A 40 °C - 3 min
      1600 A 40 °C - 10 min
      associated fuse rating
      630 A aM at <= 440 V
      1000 A gG at <= 440 V
      average impedance
      0.12 mOhm - Ith 1000 A 50 Hz
      [Ui] rated insulation voltage
      1000 V conforming to IEC 60947-4-1
      1500 V conforming to VDE 0110 group C
      power dissipation per pole
      120 W AC-1
      control circuit voltage limits
      Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil
      Drop-out: 0.25...0.5 Uc AC 40...400 Hz with LX1/LX9 coil
      Operational: 0.85...1.1 Uc DC with LX4 coil
      Drop-out: 0.2...0.35 Uc DC with LX4 coil
      heat dissipation
      20 W
      operating time
      40...80 ms closing for with LX1/LX9 coil
      100...200 ms opening for with LX1/LX9 coil
      60...70 ms closing for with LX4 coil
      40...50 ms opening for with LX4 coil
      mounting support
      Plate
      standards
      EN 60947-4-1
      IEC 60947-4-1
      IEC 60947-1
      JIS C8201-4-1
      EN 60947-1
      product certifications
      ABS
      UL
      RINA
      DNV
      CSA
      CB
      LROS (Lloyds register of shipping)
      BV
      RMRoS
      connections - terminals
      Power circuit: bar 2 cable(s) - busbar cross section: 60 x 5 mm
      Power circuit: bolted connection
      Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
      Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end
      Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
      Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end
      Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²
      Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²
      tightening torque
      Power circuit: 58 N.m
      Control circuit: 1.2 N.m
      mechanical durability
      5 Mcycles
      inrush power in VA
      1500…1730 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
      1420…1920 VA (at 20 °C)with LX4 coil
      hold-in power consumption in VA
      20…25 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
      6.5…12.5 VA (at 20 °C)with LX4 coil
      maximum operating rate
      1200 cyc/h 55 °C
      compatibility code
      LC1F
      Environment
      IP degree of protection
      IP20 front face with shrouds conforming to IEC 60529
      IP20 front face with shrouds conforming to VDE 0106
      protective treatment
      TH
      ambient air temperature for operation
      -5…55 °C
      ambient air temperature for storage
      -60…80 °C
      permissible ambient air temperature around the device
      -40…70 °C
      mechanical robustness
      Vibrations contactor open: 2 Gn, 5...300 Hz
      Vibrations contactor closed: 4 Gn, 5...300 Hz
      Shocks contactor open: 6 Gn for 1/2 sine wave (11 ms)
      Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms)
      height
      304 mm
      width
      389 mm
      depth
      255 mm
      net weight
      21.5 kg
      Packing Units
      Unit Type of Package 1
      PCE
      Number of Units in Package 1
      1
      Package 1 Weight
      21 kg
      Package 1 Height
      33 cm
      Package 1 width
      33.5 cm
      Package 1 Length
      52 cm
      Unit Type of Package 2
      P06
      Number of Units in Package 2
      4
      Package 2 Weight
      92.5 kg
      Package 2 Height
      80 cm
      Package 2 width
      80 cm
      Package 2 Length
      60 cm
      Offer Sustainability
      Sustainable offer status
      Green Premium product
      REACh Regulation
      EU RoHS Directive
      Mercury free
      Yes
      RoHS exemption information
      China RoHS Regulation
      China RoHS declaration
      Product out of China RoHS scope. Substance declaration for your information
      Environmental Disclosure
      Circularity Profile
      WEEE
      The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
      California proposition 65
      WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
      Contractual warranty
      Warranty
      18 months
    • View more
      View less

      Documents

      Language
      • All Languages18
      • English17
      • Chinese5
      • French8
      • German5
      • Italian5
      • Portuguese5
      • Russian5
      • Spanish5
      Catalogue
      Format
      Size
      Date
      Add to My Documents
      TeSys - Catalogue 2020 - Innovative and connected solutions for motor starters (Version 10.0)
      Description
      Ready-to-use motor starters and all components for building specific motor starters ( circuit breakers, contactors, overload relays , accessories ...). This edition includes a presentation of the new TeSys island system. The catalogue can also be downloaded chapter per chapter.
      prp.document.label.format pdf
      Size 118.2 MB
      Date 7/22/20
      Description
      Ready-to-use motor starters and all components for building specific motor starters ( circuit breakers, contactors, overload relays , accessories ...). This edition includes a presentation of the new TeSys island system. The catalogue can also be downloaded chapter per chapter.
      TeSys catalogue - 2020 - chapter A6 - Circuit breaker + contactor coordination tables and design guidelines (Version 7.0)
      Description
      Coordination between protection & control components; Suggested coordinated DOL motor starters combinations; Suggested coordinated Star-delta motor starters combinations;Contactors : utilization categories; standard characteristics, sel. tables per categories Contactors for specific application; standards, protection against contact, protective treatments Included : TeSys island coordination tables
      prp.document.label.format pdf
      Size 3.7 MB
      Date 7/22/20
      Description
      Coordination between protection & control components; Suggested coordinated DOL motor starters combinations; Suggested coordinated Star-delta motor starters combinations;Contactors : utilization categories; standard characteristics, sel. tables per categories Contactors for specific application; standards, protection against contact, protective treatments Included : TeSys island coordination tables
      Certificate
      Format
      Size
      Date
      Add to My Documents
      prp.document.label.format pdf
      Size 420.1 KB
      Date 4/2/20
      prp.document.label.format pdf
      Size 1.8 MB
      Date 4/17/17
      Instruction sheet
      Format
      Size
      Date
      Add to My Documents
      prp.document.label.format pdf
      Size 4.5 MB
      Date 4/1/19
      prp.document.label.format pdf
      Size 6 MB
      Date 1/2/19
      prp.document.label.format pdf
      Size 2.7 MB
      Date 5/2/17
      prp.document.label.format pdf
      Size 3.2 MB
      Date 4/1/16
      China RoHS declaration
      Format
      Size
      Date
      Add to My Documents
      LC1F6304 : TeSys F contactor - 4P(4 NO) - AC-1 - <= 440 V 1000 A - without coil
      Description
      TeSys F contactor - 4P(4 NO) - AC-1 - <= 440 V 1000 A - without coil
      prp.document.label.format pdf
      Size 195.3 KB
      Date 5/23/21
      Description
      TeSys F contactor - 4P(4 NO) - AC-1 - <= 440 V 1000 A - without coil
      Declaration of conformity
      Format
      Size
      Date
      Add to My Documents
      prp.document.label.format pdf
      Size 488.5 KB
      Date 12/3/20
      End of Life Information
      Format
      Size
      Date
      Add to My Documents
      prp.document.label.format pdf
      Size 391.6 KB
      Date 12/18/18
      TeSys LC1 F330-1250 - EoLi (Version 1.0)
      Description
      TeSys LC1 F330-1250 - EoLi
      prp.document.label.format pdf
      Size 200.1 KB
      Date 7/1/15
      Description
      TeSys LC1 F330-1250 - EoLi
      EU RoHS Declaration
      Format
      Size
      Date
      Add to My Documents
      LC1F6304 : TeSys F contactor - 4P(4 NO) - AC-1 - <= 440 V 1000 A - without coil
      Description
      TeSys F contactor - 4P(4 NO) - AC-1 - <= 440 V 1000 A - without coil
      prp.document.label.format pdf
      Size 195.3 KB
      Date 5/23/21
      Description
      TeSys F contactor - 4P(4 NO) - AC-1 - <= 440 V 1000 A - without coil
      Product Environmental Profile
      Format
      Size
      Date
      Add to My Documents
      TeSys LC1F330-1250 - PEP (Version 1.0)
      Description
      TeSys LC1F330-1250 - PEP
      prp.document.label.format pdf
      Size 202.6 KB
      Date 7/1/15
      Description
      TeSys LC1F330-1250 - PEP
      REACh Declaration
      Format
      Size
      Date
      Add to My Documents
      LC1F6304 : TeSys F contactor - 4P(4 NO)-AC-1 <= 440V 1000A with coil LX1/ LX9 - 48…1000V AC 40/400Hz, LX4 - 48...440V DC
      Description
      TeSys F contactor - 4P(4 NO)-AC-1 <= 440V 1000A with coil LX1/ LX9 - 48…1000V AC 40/400Hz, LX4 - 48...440V DC
      prp.document.label.format pdf
      Size 195.3 KB
      Date 5/23/21
      Description
      TeSys F contactor - 4P(4 NO)-AC-1 <= 440V 1000A with coil LX1/ LX9 - 48…1000V AC 40/400Hz, LX4 - 48...440V DC
    • Technical FAQs

      No results found.
      Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
      • Is our Tesys F contactor double break pole type contactor

        Tesys F (LC1F*) uses linear translation movement of contacts,hence double break pole type operation is obtained.

      • What is ECM for Tesys F contactors and what is its application

        ECM is an Electronic Control Module is an external module, to operate TeSys F contactors with range of control voltage (50.. ...

      • Is it possible to add main pole to Tesys F contactor? For example to change 3-pole contactor to 4-pole contactor?

        No, it is not possible to add main pole to Tesys F contactors. Only auxiliary contacts can be added but not main pole.

      • Can you please confirm the Tesys LC1D contactors are suitable to select & install in use of Seismic zone II A ?

        Contactor, Tesys D, Tesys F , LC1D, LC1F, Seismic zone II A, Vibration, Shocks

      • What is the difference between LX1 and LX9 coil?

        Product Line: Tesys F line Contactors and Accessories

    Loading